Print
ACE-716T
Price: 171$

 add to my interests


Detailed features:
Rugged AT 150W -48V DC input power supply

Intput Table
ACE-716A/AP: 85~135V or 180~265V AC' 47 to 440Hz, 4A@115V or 2A@230V AC
ACE-716C: +19 to +30V DC, 12A@+24V DC
ACE-716T: -36 to -72V DC, 6A@-48V DC
Output Table:
ACE-716A/AP:
Rated Load +5V:18A +12V:4A -5V:0.5A -12V:1A
Max. Output +5V:25A +12V:10A -5V:1A -12V:1A
ACE-716C:
Rated Load +5V:18A +12V:4A -5V:0.5A -12V:1A
Max. Output +5V:25A +12V:10A -5V:1A -12V:1.5A
ACE-716T:
Rated Load +5V:18A +12V:4A -5V:0.5A -12V:1A
Max. Output +5V:25A +12V:10A -5V:1A -12V:1.5A
Inrush Current (ACE-716A/716AP)
Not exceed 15A@115V AC or 30A@230V AC
Ripple and Noise
Less than 100mV
Line Regulation
The line regulation for each outputs are less than +/-1%, while measuring at rated loading and +/-10% of input voltage changing
Load Regulation
- ACE-716A/716AP : Less than +/-3%@+/-5V and -12V, +/-6%@+12V
- ACE-716T/C : Less than +/-1%@+/-5V and -12V, +/-4%@+12V
Efficiency
- ACE-716A/716AP : Higher than 75%
- ACE-716T/C : Higher than 70%
Hold-up Time (ACE-716A/716AP)
20ms (typical)@115V AC
Altitude
0 ~ 10,000ft
Protection
Over voltage protection. The trip point is around 5.9V ~ 7.0V output
Thermal Protection
Built in 110șC thermal switch in HS1
Vibration
10 ~ 55Hz at 2G 3min. period, 30 min. along X, Y and Z axis
Impact
10G for 20ms once on each X, Y and Z axis
Hi-pot isolation
- 4300V DC, input to output for one minute
- 2200V DC, input to ground for one minute
MTBF
- ACE-716A : 188,800 hours
- ACE-716T : 212,050 hours
- ACE-716C : 187,490 hours
Safety
Meets UL 478, 1012, 1950; CSA 22.2 No. 234, VDE EN 60950
EMI
- Meets FCC docket 20780 curve "A", EN50081-2 : CISPR22 "A"
- Harmonic EN 61000-3-2 for ACE-716AP
EMS Standard (Designed to meet the following limits)
- EN 50082-2
- IEC 801-1 8KV (Air Discharge) criteria B (ACE-716A/716AP)
- IEC 801-3, 10V/M criteria A
- IEC 801-4, 2KV criteria B (ACE-716A/716AP)
- IEC 801-5, 2KV criteria B (ACE-716A/716AP)
Built-in cooling fan
Operating Temperature
-20șC ~ 70șC
(Derating curve will occur 50șC ~ 70șC)
Storage Temperature
-20șC ~ 85șC
Dimensions
97(W) x 40.5(H) x 198(D)mm; (3.8" x 1.6" x 7.8")

Specifications:
Impact10G for 20ms once on each X, Y and Z axis
Hi-pot isolation- 4300V DC, input to output for one minute
- 2200V DC, input to ground for one minute
SafetyMeets UL 478, 1012, 1950; CSA 22.2 No. 234, VDE EN 60950
Operating Temperature-20șC ~ 70șC
Storage Temperature-20șC ~ 85șC
Dimensions97(W) x 40.5(H) x 198(D)mm; (3.8" x 1.6" x 7.8")

Contact us
Send us your interests


Copyrights 2005 © All rights reserved Techmatron inc. All prices in Canadian dollars. Subject to change without notice. credits