ISO-LDH
Isolated Strain Gauge type Loadcell Input Board ( High Gain) FEATURES The ISO-LD series is a bus-type isolated loadcell input board. The isolation inputs can operate with up to 500Vrms of common-mode voltage. The ISO-LD series features a 12-bit analog-to-digital converter, on board 1 K bytes FIFO buffer , one loadcell signal input channel, one analog input channel, 8-channel 12-24V isolated digital inputs, 7-channel isolated open-collector digital outputs, one programmable 8-bit LED indicator to indicate the magnitude of strain gauge input signal. The ISO-LD series board is suitable for static force measurement and dynamic force analysis. Because there are on board excitation voltage, high gain amplifier, you don*t have to buy any excitation voltage and signal conditioning module. In other words, it save your money and space. The board also have some special features, such as: 12-bit programmable offset voltage. Therefore the user can cancel the DC bias and amplify the AC signal The isolated structure eliminate the ground loop noise and protect your computer. On board FIFO buffer support gap-free A/D conversion under DOS and Windows environment. Except the loadcell input channel, there are a lot digital I/O and one analog input channel .The user can implement a measurement and analysis system. AT bus 500 VDC photo-isolation protection One channel strain gauge input channel One channel analog input channel Built-in 1K bytes FIFO Excitation voltage for loadcell : 12V, 50mA Maximum gain up to 40,000 Programmable 12 bit resolution ,DC offset voltage (0~5V) Second order low pass filter build-in Direct connection to strain gauge type loadcell 8-channel 12-24V isolated digital input 7-channel isolated open-collector digital output Programmable 8 bits LED indicator. Command set programming SPECIFICATIONS: Analog Input Specifications Channels: 1 loadcell input channel & 1 analog input channel Resolution: 12-bit Sampling Rate: 20KS/s max Nonlinearity: ±0.01% Gain error: 0.005% of reading maximum Input Impedance: 10,000MW||6pF Bias current: ±2 nA (maximum) Input offset current: ±2 nA (maximum) CMRR: 90 dB (Minimum) Recommended warm-up time: 10 minutes Sample & hold: On chip ISO-LDH Input Range Analog input range 0~10V , 0 ~1V , 0~0.1V , 0~0.01V Strain Gauge input range 0 ~ 37.5mV Resolution 12-bits Gain Input range 400 0~37.5 4,000 0~15 40,000 0~12.75 ISO-LDL Input Range Normal input range 0~10V, 0~5V, 0~2.5V, 0~1.25V Loadcell input range 0 to 37.5mV Loadcell offset voltage adjustment 0 to -5V, 8 bit Gain input range(mV): 400 0 ~ 37.5 / 8,00 0 ~ 25 / 1,600 0 ~ 18.75 / 3,200 0 ~ 15.625 Loadcell offset voltage adjustment: 0 to 5V, 12 bit resolution Digital I/O digital input 8 photo-isolated 12~24V digital output 7 isolated open-collector (100mA) Output 8 TTL/LED Environmental Operating Temperature: -25ºC - 75ºC Storage Temp: -20°C to 70°C Humidity: 0-90%, non-condensing Dimensions: 190cm x 122cm Power Requirements: +5V @ 400mA max. Applications Strain gauge type loadcell measurement Dynamic force on line monitoring system Dynamic pressure measurement
$1087.00
ISO-LDHS
Isolated Strain Gauge type Loadcell Input Board ( High Gain) FEATURES The ISO-LD series is a bus-type isolated loadcell input board. The isolation inputs can operate with up to 500Vrms of common-mode voltage. The ISO-LD series features a 12-bit analog-to-digital converter, on board 1 K bytes FIFO buffer , one loadcell signal input channel, one analog input channel, 8-channel 12-24V isolated digital inputs, 7-channel isolated open-collector digital outputs, one programmable 8-bit LED indicator to indicate the magnitude of strain gauge input signal. The ISO-LD series board is suitable for static force measurement and dynamic force analysis. Because there are on board excitation voltage, high gain amplifier, you don*t have to buy any excitation voltage and signal conditioning module. In other words, it save your money and space. The board also have some special features, such as: 12-bit programmable offset voltage. Therefore the user can cancel the DC bias and amplify the AC signal The isolated structure eliminate the ground loop noise and protect your computer. On board FIFO buffer support gap-free A/D conversion under DOS and Windows environment. Except the loadcell input channel, there are a lot digital I/O and one analog input channel .The user can implement a measurement and analysis system. AT bus 500 VDC photo-isolation protection One channel strain gauge input channel One channel analog input channel Built-in 1K bytes FIFO Excitation voltage for loadcell : 12V, 50mA Maximum gain up to 40,000 Programmable 12 bit resolution ,DC offset voltage (0~5V) Second order low pass filter build-in Direct connection to strain gauge type loadcell 8-channel 12-24V isolated digital input 7-channel isolated open-collector digital output Programmable 8 bits LED indicator. Command set programming SPECIFICATIONS: Analog Input Specifications Channels: 1 loadcell input channel & 1 analog input channel Resolution: 12-bit Sampling Rate: 20KS/s max Nonlinearity: ±0.01% Gain error: 0.005% of reading maximum Input Impedance: 10,000MW||6pF Bias current: ±2 nA (maximum) Input offset current: ±2 nA (maximum) CMRR: 90 dB (Minimum) Recommended warm-up time: 10 minutes Sample & hold: On chip ISO-LDH Input Range Analog input range 0~10V , 0 ~1V , 0~0.1V , 0~0.01V Strain Gauge input range 0 ~ 37.5mV Resolution 12-bits Gain Input range 400 0~37.5 4,000 0~15 40,000 0~12.75 ISO-LDL Input Range Normal input range 0~10V, 0~5V, 0~2.5V, 0~1.25V Loadcell input range 0 to 37.5mV Loadcell offset voltage adjustment 0 to -5V, 8 bit Gain input range(mV): 400 0 ~ 37.5 / 8,00 0 ~ 25 / 1,600 0 ~ 18.75 / 3,200 0 ~ 15.625 Loadcell offset voltage adjustment: 0 to 5V, 12 bit resolution Digital I/O digital input 8 photo-isolated 12~24V digital output 7 isolated open-collector (100mA) Output 8 TTL/LED Environmental Operating Temperature: -25ºC - 75ºC Storage Temp: -20°C to 70°C Humidity: 0-90%, non-condensing Dimensions: 190cm x 122cm Power Requirements: +5V @ 400mA max. Applications Strain gauge type loadcell measurement Dynamic force on line monitoring system Dynamic pressure measurement
$1233.00
ISO-LDL
Isolated Strain Gauge type Loadcell Input Board ( Low Gain) FEATURES: The ISO-LD series is a bus-type isolated loadcell input board. The isolation inputs can operate with up to 500Vrms of common-mode voltage. The ISO-LD series features a 12-bit analog-to-digital converter, on board 1 K bytes FIFO buffer , one loadcell signal input channel, one analog input channel, 8-channel 12-24V isolated digital inputs, 7-channel isolated open-collector digital outputs, one programmable 8-bit LED indicator to indicate the magnitude of strain gauge input signal. The ISO-LD series board is suitable for static force measurement and dynamic force analysis. Because there are on board excitation voltage, high gain amplifier, you don*t have to buy any excitation voltage and signal conditioning module. In other words, it save your money and space. The board also have some special features, such as: 12-bit programmable offset voltage. Therefore the user can cancel the DC bias and amplify the AC signal The isolated structure eliminate the ground loop noise and protect your computer. On board FIFO buffer support gap-free A/D conversion under DOS and Windows environment. Except the loadcell input channel, there are a lot digital I/O and one analog input channel .The user can implement a measurement and analysis system. AT bus 500 VDC photo-isolation protection One channel strain gauge input channel One channel analog input channel Built-in 1K bytes FIFO Excitation voltage for loadcell : 12V, 50mA Maximum gain up to 40,000 Programmable 12 bit resolution ,DC offset voltage (0~5V) Second order low pass filter build-in Direct connection to strain gauge type loadcell 8-channel 12-24V isolated digital input 7-channel isolated open-collector digital output Programmable 8 bits LED indicator. Command set programming SPECIFICATIONS: Analog Input Specifications Channels: 1 loadcell input channel & 1 analog input channel Resolution: 12-bit Sampling Rate: 20KS/s max Nonlinearity: ±0.01% Gain error: 0.005% of reading maximum Input Impedance: 10,000MW||6pF Bias current: ±2 nA (maximum) Input offset current: ±2 nA (maximum) CMRR: 90 dB (Minimum) Recommended warm-up time: 10 minutes Sample & hold: On chip ISO-LDH Input Range Analog input range: 0~10V , 0 ~1V , 0~0.1V , 0~0.01V Strain Gauge input range: 0 ~ 37.5mV Resolution: 12-bits Gain Input Range: 400 0~37.5 4,000 0~15 40,000 0~12.75 ISO-LDL Input Range Normal input range: 0~10V, 0~5V, 0~2.5V, 0~1.25V Loadcell input range: 0 to 37.5mV Loadcell offset voltage adjustment: 0 to -5V, 8 bit Gain input range(mV): 400 0 ~ 37.5 / 8,00 0 ~ 25 / 1,600 0 ~ 18.75 / 3,200 0 ~ 15.625 Loadcell offset voltage adjustment: 0 to 5V, 12 bit resolution Digital I/O Digital Input: 8 photo-isolated 12~24V Digital Output: 7 isolated open-collector (100mA) Output: 8 TTL/LED Environmental Operation Temp. 0°C to 50°C Storage Temp: -20°C to 70°C Humidity: 0-90%, non-condensing Dimensions: 190cm x 122cm Power Requirements: +5V @ 400mA max. Applications Strain gauge type loadcell measurement Dynamic force on line monitoring system Dynamic pressure measurement
$1087.00
ISO-LDLS
Isolated Strain Gauge type Loadcell Input Board ( Low Gain) ISO-LDLS with DN-25 FEATURES: The ISO-LD series is a bus-type isolated loadcell input board. The isolation inputs can operate with up to 500Vrms of common-mode voltage. The ISO-LD series features a 12-bit analog-to-digital converter, on board 1 K bytes FIFO buffer , one loadcell signal input channel, one analog input channel, 8-channel 12-24V isolated digital inputs, 7-channel isolated open-collector digital outputs, one programmable 8-bit LED indicator to indicate the magnitude of strain gauge input signal. The ISO-LD series board is suitable for static force measurement and dynamic force analysis. Because there are on board excitation voltage, high gain amplifier, you don*t have to buy any excitation voltage and signal conditioning module. In other words, it save your money and space. The board also have some special features, such as: 12-bit programmable offset voltage. Therefore the user can cancel the DC bias and amplify the AC signal The isolated structure eliminate the ground loop noise and protect your computer. On board FIFO buffer support gap-free A/D conversion under DOS and Windows environment. Except the loadcell input channel, there are a lot digital I/O and one analog input channel .The user can implement a measurement and analysis system. AT bus 500 VDC photo-isolation protection One channel strain gauge input channel One channel analog input channel Built-in 1K bytes FIFO Excitation voltage for loadcell : 12V, 50mA Maximum gain up to 40,000 Programmable 12 bit resolution ,DC offset voltage (0~5V) Second order low pass filter build-in Direct connection to strain gauge type loadcell 8-channel 12-24V isolated digital input 7-channel isolated open-collector digital output Programmable 8 bits LED indicator. Command set programming SPECIFICATIONS: Analog Input Specifications Channels: 1 loadcell input channel & 1 analog input channel Resolution: 12-bit Sampling Rate: 20KS/s max Nonlinearity: ±0.01% Gain error: 0.005% of reading maximum Input Impedance: 10,000MW||6pF Bias current: ±2 nA (maximum) Input offset current: ±2 nA (maximum) CMRR: 90 dB (Minimum) Recommended warm-up time: 10 minutes Sample & hold: On chip ISO-LDH Input Range Analog input range: 0~10V , 0 ~1V , 0~0.1V , 0~0.01V Strain Gauge input range: 0 ~ 37.5mV Resolution: 12-bits Gain Input Range: 400 0~37.5 4,000 0~15 40,000 0~12.75 ISO-LDL Input Range Normal input range: 0~10V, 0~5V, 0~2.5V, 0~1.25V Loadcell input range: 0 to 37.5mV Loadcell offset voltage adjustment: 0 to -5V, 8 bit Gain input range(mV): 400 0 ~ 37.5 / 8,00 0 ~ 25 / 1,600 0 ~ 18.75 / 3,200 0 ~ 15.625 Loadcell offset voltage adjustment: 0 to 5V, 12 bit resolution Digital I/O Digital Input: 8 photo-isolated 12~24V Digital Output: 7 isolated open-collector (100mA) Output: 8 TTL/LED Environmental Operation Temp. 0°C to 50°C Storage Temp: -20°C to 70°C Humidity: 0-90%, non-condensing Dimensions: 190cm x 122cm Power Requirements: +5V @ 400mA max. Applications Strain gauge type loadcell measurement Dynamic force on line monitoring system Dynamic pressure measurement
$1233.00
PCI-1002L
Isolated Strain Gauge type Loadcell Input Board ( Low Gain) FEATURES: PCI bus 12-bit 110KHz A/D converter PCI-1002H/-1002L ,32 single-ended/ 16 differential inputs The sampling rates of single channel or multiple Channels is 110 K samples/s Three different external trigger : post-trigger, pre-trigger, middle trigger 16 digital input / 16 digital output channels 1002L : programmable low gain:1, 2, 4, 8. 1002H: programmable high gain:1, 10, 100, 1000. Internal / external trigger. Half size board SPECIFICATIONS Digital I/O Inputs : 16 channels ; TTL levels Outputs : 16 channels ; TTL levels Timer Counter Internal pacer timer : 16 bit, 8MHz input External pacer timer : 16 bit, 8MHz input Machine independent timer : 16 bit, 8MHz input Power Requirements : +5V 350mA (max) Environment Operating temp.: 0°C - 50°C Storage temp.: -20°C to 70°C Humility: 0 to 90% non-condensing Dimensions: 175 mm x 105 mm
$609.00
PCI-1002LS
Isolated Strain Gauge type Loadcell Input Board ( Low Gain) PCI-1202L with DB-1825 daughter board ,cable FEATURES: PCI bus 12-bit 110KHz A/D converter PCI-1002H/-1002L ,32 single-ended/ 16 differential inputs The sampling rates of single channel or multiple Channels is 110 K samples/s Three different external trigger : post-trigger, pre-trigger, middle trigger 16 digital input / 16 digital output channels 1002L : programmable low gain:1, 2, 4, 8. 1002H: programmable high gain:1, 10, 100, 1000. Internal / external trigger. Half size board SPECIFICATIONS Digital I/O Inputs : 16 channels ; TTL levels Outputs : 16 channels ; TTL levels Timer Counter Internal pacer timer : 16 bit, 8MHz input External pacer timer : 16 bit, 8MHz input Machine independent timer : 16 bit, 8MHz input Power Requirements : +5V 350mA (max) Environment Operating temp.: 0°C - 50°C Storage temp.: -20°C to 70°C Humility: 0 to 90% non-condensing Dimensions: 175 mm x 105 mm
$753.00
PCI-1002HS
Isolated Strain Gauge type Loadcell Input Board ( High Gain) PCI-1002H with DB-1825 daughter board , Cable FEATURES: PCI bus 12-bit 110KHz A/D converter PCI-1002H/-1002L, 32 single-ended/ 16 differential inputs The sampling rates of single channel or multiple Channels is 110 K samples/s Three different external trigger : post-trigger, pre-trigger, middle trigger 16 digital input / 16 digital output channels 1002L : programmable low gain:1, 2, 4, 8. 1002H: programmable high gain:1, 10, 100, 1000. Internal / external trigger. Half size board SPECIFICATIONS: Digital I/O Inputs : 16 channels ; TTL levels Outputs : 16 channels ; TTL levels Timer Counter Internal pacer timer : 16 bit, 8MHz input External pacer timer : 16 bit, 8MHz input Machine independent timer : 16 bit, 8MHz input Power Requirements : +5V 350mA (max) Environment Operating temp.: 0°C - 50°C Storage temp.: -20°C to 70°C Humidity: 0 to 90% non-condensing Dimensions: 175 mm x 105 mm
$753.00
PCI-1002H
Isolated Strain Gauge type Loadcell Input Board ( High Gain) FEATURES: PCI bus 12-bit 110KHz A/D converter PCI-1002H/-1002L, 32 single-ended/ 16 differential inputs The sampling rates of single channel or multiple Channels is 110 K samples/s Three different external trigger : post-trigger, pre-trigger, middle trigger 16 digital input / 16 digital output channels 1002L : programmable low gain:1, 2, 4, 8. 1002H: programmable high gain:1, 10, 100, 1000. Internal / external trigger. Half size board SPECIFICATIONS: Digital I/O Inputs : 16 channels ; TTL levels Outputs : 16 channels ; TTL levels Timer Counter Internal pacer timer : 16 bit, 8MHz input External pacer timer : 16 bit, 8MHz input Machine independent timer : 16 bit, 8MHz input Power Requirements : +5V 350mA (max) Environment Operating temp.: 0°C - 50°C Storage temp.: -20°C to 70°C Humidity: 0 to 90% non-condensing Dimensions: 175 mm x 105 mm
$609.00