Industrial Automation | Distributed I/O Modules

MA-12

MA-12

Output type MagicWire for PLC Introduction The FRnet network only requires a single hostcontroller to send a token that activates all FRnet I/O modules. Two host controllers cannot be used in the same FRnet network. The MA-11, MD-11, FRB-100/200, I-7188EF, I-8122 and some FR I/O modules can be used as FRnet host-controllers. When using an MA-11, MD-11 or FR I/O module as a host-controller, the switch or jumper should be set to the A1 position. Refer to the related user's manual or literature for detailed information. When using the FRB-2000, I-7188EF or I-8122, the switch doesn't have to be set. Specifications Communication speed: 250K bps Communication distance: 400m max Digital input channels: 32 (MD-11, MD-11M) Digital output channels: 32 (MD-12, MD-12M) Connector type: 37-pin D-sub female connector (MD-11, MD-12) 37-pin D-sub male connector (MD-11M, MD-12M) Power requirements: 12~24V Wire cable: CPEV 0.9S (2P twisted-pair wire) Power consumption: 1.2 W Dimensions: 120 mm x 90 mm Operating temperature: -25¢XC ~ +75¢XC Operating humidity: 10% ~ 90% RH, non-condensing Storage temperature: -30¢XC ~ +85¢XC Storage humidity: 5% ~ 95% RH, non-condensing Dimensions: 76 mm x 73 mm x 15 mm

Call Us

MA-22

MA-22

Output type MagicWire for PLC Introduction The FRnet network only requires a single hostcontroller to send a token that activates all FRnet I/O modules. Two host controllers cannot be used in the same FRnet network. The MA-11, MD-11, FRB-100/200, I-7188EF, I-8122 and some FR I/O modules can be used as FRnet host-controllers. When using an MA-11, MD-11 or FR I/O module as a host-controller, the switch or jumper should be set to the A1 position. Refer to the related user's manual or literature for detailed information. When using the FRB-2000, I-7188EF or I-8122, the switch doesn't have to be set. Specifications Communication speed: 250K bps Communication distance: 400m max Digital input channels: 32 (MD-11, MD-11M) Digital output channels: 32 (MD-12, MD-12M) Connector type: 37-pin D-sub female connector (MD-11, MD-12) 37-pin D-sub male connector (MD-11M, MD-12M) Power requirements: 12~24V Wire cable: CPEV 0.9S (2P twisted-pair wire) Power consumption: 1.2 W Dimensions: 120 mm x 90 mm Operating temperature: -25¢XC ~ +75¢XC Operating humidity: 10% ~ 90% RH, non-condensing Storage temperature: -30¢XC ~ +85¢XC Storage humidity: 5% ~ 95% RH, non-condensing Dimensions: 76 mm x 73 mm x 15 mm

Call Us

MD-11

MD-11

Input type MagicWire for I-8000 Introduction The MD-11M is an input type module featuring a male 37-pin D-sub connector that works with ISO-C64 or PISO-C64 PCI-based digital I/O boards. The MD-12M is an output type module featuring a male 37-pin D-sub connector that works with ISO-P64 or PISO-P64 PCI-based digital I/O boards. The MD-11 features a female 37-pin D-sub connector and works with I-8041 or I-87041. The MD-12 features a female 37-pin D-sub connector and works with I-8040 or I-87040. The I-8041, I-87041, I-8042, I-87042 are all digital series I-8000 PAC and WinCon-8000. Specifications Communication speed: 250K bps Communication distance: 400m max Digital input channels: 32 (MD-11, MD-11M) Digital output channels: 32 (MD-12, MD-12M) Connector type: 37-pin D-sub female connector (MD-11, MD-12) 37-pin D-sub male connector (MD-11M, MD-12M) Power requirements: 12~24V Wire cable: CPEV 0.9S (2P twisted-pair wire) Power consumption: 1.2 W Operating temperature: -25¢XC ~ +75¢XC Operating humidity: 10% ~ 90% RH, non-condensing Storage temperature: -30¢XC ~ +85¢XC Storage humidity: 5% ~ 95% RH, non-condensing Dimensions: 76 mm x 73 mm x 15 mm

Call Us

MD-11M

MD-11M

Input type MagicWire for PC I/O card Introduction The MD-11M is an input type module featuring a male 37-pin D-sub connector that works with ISO-C64 or PISO-C64 PCI-based digital I/O boards. The MD-12M is an output type module featuring a male 37-pin D-sub connector that works with ISO-P64 or PISO-P64 PCI-based digital I/O boards. The MD-11 features a female 37-pin D-sub connector and works with I-8041 or I-87041. The MD-12 features a female 37-pin D-sub connector and works with I-8040 or I-87040. The I-8041, I-87041, I-8042, I-87042 are all digital series I-8000 PAC and WinCon-8000. Specifications Communication speed: 250K bps Communication distance: 400m max Digital input channels: 32 (MD-11, MD-11M) Digital output channels: 32 (MD-12, MD-12M) Connector type: 37-pin D-sub female connector (MD-11, MD-12) 37-pin D-sub male connector (MD-11M, MD-12M) Power requirements: 12~24V Wire cable: CPEV 0.9S (2P twisted-pair wire) Power consumption: 1.2 W Operating temperature: -25¢XC ~ +75¢XC Operating humidity: 10% ~ 90% RH, non-condensing Storage temperature: -30¢XC ~ +85¢XC Storage humidity: 5% ~ 95% RH, non-condensing Dimensions: 76 mm x 73 mm x 15 mm

Call Us

MD-12M

MD-12M

Output type MagicWire for PC I/O card Introduction The MD-11M is an input type module featuring a male 37-pin D-sub connector that works with ISO-C64 or PISO-C64 PCI-based digital I/O boards. The MD-12M is an output type module featuring a male 37-pin D-sub connector that works with ISO-P64 or PISO-P64 PCI-based digital I/O boards. The MD-11 features a female 37-pin D-sub connector and works with I-8041 or I-87041. The MD-12 features a female 37-pin D-sub connector and works with I-8040 or I-87040. The I-8041, I-87041, I-8042, I-87042 are all digital series I-8000 PAC and WinCon-8000. Specifications Communication speed: 250K bps Communication distance: 400m max Digital input channels: 32 (MD-11, MD-11M) Digital output channels: 32 (MD-12, MD-12M) Connector type: 37-pin D-sub female connector (MD-11, MD-12) 37-pin D-sub male connector (MD-11M, MD-12M) Power requirements: 12~24V Wire cable: CPEV 0.9S (2P twisted-pair wire) Power consumption: 1.2 W Operating temperature: -25¢XC ~ +75¢XC Operating humidity: 10% ~ 90% RH, non-condensing Storage temperature: -30¢XC ~ +85¢XC Storage humidity: 5% ~ 95% RH, non-condensing Dimensions: 76 mm x 73 mm x 15 mm

Call Us

MD-12

MD-12

Output type MagicWire for I-8000 Introduction The MD-11M is an input type module featuring a male 37-pin D-sub connector that works with ISO-C64 or PISO-C64 PCI-based digital I/O boards. The MD-12M is an output type module featuring a male 37-pin D-sub connector that works with ISO-P64 or PISO-P64 PCI-based digital I/O boards. The MD-11 features a female 37-pin D-sub connector and works with I-8041 or I-87041. The MD-12 features a female 37-pin D-sub connector and works with I-8040 or I-87040. The I-8041, I-87041, I-8042, I-87042 are all digital series I-8000 PAC and WinCon-8000. Specifications Communication speed: 250K bps Communication distance: 400m max Digital input channels: 32 (MD-11, MD-11M) Digital output channels: 32 (MD-12, MD-12M) Connector type: 37-pin D-sub female connector (MD-11, MD-12) 37-pin D-sub male connector (MD-11M, MD-12M) Power requirements: 12~24V Wire cable: CPEV 0.9S (2P twisted-pair wire) Power consumption: 1.2 W Operating temperature: -25¢XC ~ +75¢XC Operating humidity: 10% ~ 90% RH, non-condensing Storage temperature: -30¢XC ~ +85¢XC Storage humidity: 5% ~ 95% RH, non-condensing Dimensions: 76 mm x 73 mm x 15 mm

Call Us

FR-8

FR-8

8-channel Digital Input Module Functional Description The FR-8/16/32P has 8/16/32-channel isolated digital input. Not like traditional digital I/O board, the FR series I/O module has an FRnet interface. It can be used as a distributed remote I/O module or a MagicWire module. The user should select the correct setting when using these functions. The user can daisy chain several FRnet modules together. Via FRnet, the FRnet modules can extend the remote I/O of PC, PAC, £gPAC and PLC easily. Further information about the networking of FR-8/6/32P, refer to our I-7188EF, I-8122, FRB-100/200. Applications Factory Automation Building automation Energy management Agriculture automation Specifications Communication speed: 250K bps Communication distance: 400m max Number of channels: 8/16/32 ( FR-8/16/32P) Digital Logic Level Input low voltage: 0 ~ +/-1V Input high voltage: 3.5 VDC ~ 30 VDC Input impedance: 3K; 1/4W Response time: 1 KHz max Power Requirement: 10~30V Wire cable: CPEV 0.9S (2P Twisted-pair wire) Power consumption: 24V@25mA(max) ( FR-8P) 24V@75mA(max) ( FR-16P) 24V@140mA(max) ( FR-32P) Operating temperature: -25¢XC ~ +75¢XC Operating humidity: 10% ~ 90% RH, non-condensing Storage temperature: -30¢XC ~ +85¢XC Storage humidity: 5% ~ 95% RH, non-condensing Dimensions: 103 mm x 86 mm ( FR-8P) 147 mm x 76 mm (FR-16P) 173 mm x 117 mm (FR-32P) Features Built-in FRnet interface Real I/O synchronization Innovative token-stream technology Support Broadcasting Real Deterministic Control Fixed Scan time: 256 points @ 2.88 ms Each bank consists of 8 input channels and has its own ground reference ASIC design without CPU Memory-map I/O No protocol and no software overhead Easy Programming and OS-independent Din-rail mounting Two-Wire Cabling Jumper setting Interface circuit

Call Us

FR-16P

FR-16P

16-channel Digital Input Module Functional Description The FR-8/16/32P has 8/16/32-channel isolated digital input. Not like traditional digital I/O board, the FR series I/O module has an FRnet interface. It can be used as a distributed remote I/O module or a MagicWire module. The user should select the correct setting when using these functions. The user can daisy chain several FRnet modules together. Via FRnet, the FRnet modules can extend the remote I/O of PC, PAC, £gPAC and PLC easily. Further information about the networking of FR-8/6/32P, refer to our I-7188EF, I-8122, FRB-100/200. Applications Factory Automation Building automation Energy management Agriculture automation Specifications Communication speed: 250K bps Communication distance: 400m max Number of channels: 8/16/32 ( FR-8/16/32P) Digital Logic Level Input low voltage: 0 ~ +/-1V Input high voltage: 3.5 VDC ~ 30 VDC Input impedance: 3K; 1/4W Response time: 1 KHz max Power Requirement: 10~30V Wire cable: CPEV 0.9S (2P Twisted-pair wire) Power consumption: 24V@25mA(max) ( FR-8P) 24V@75mA(max) ( FR-16P) 24V@140mA(max) ( FR-32P) Operating temperature: -25¢XC ~ +75¢XC Operating humidity: 10% ~ 90% RH, non-condensing Storage temperature: -30¢XC ~ +85¢XC Storage humidity: 5% ~ 95% RH, non-condensing Dimensions: 103 mm x 86 mm ( FR-8P) 147 mm x 76 mm (FR-16P) 173 mm x 117 mm (FR-32P) Features Built-in FRnet interface Real I/O synchronization Innovative token-stream technology Support Broadcasting Real Deterministic Control Fixed Scan time: 256 points @ 2.88 ms Each bank consists of 8 input channels and has its own ground reference ASIC design without CPU Memory-map I/O No protocol and no software overhead Easy Programming and OS-independent Din-rail mounting Two-Wire Cabling Jumper setting Interface circuit

Call Us

  
 