ISO-5B34-01

ISO-5B34-01

RTD (100 OHM) Input, 0 To 5 Output -100 TO +100 deg C Analog Isolation Module Features:RTD input 1500 Vrms Isolation Low CostSpecifications:Input Range: -100C to +100C Output Range: 0-5V Input Offset: ± 0.02dC/ deg C Output Offset: ± 20μV°C Output Resistance: 50 Ohm Bandwidth, -3dB: 4 Hz Output Protection: Continuous Short to Ground Isolation: 1500 Vrms CMR at 50-60 Hz: 160 dB NMR at 50-60 Hz: 90 dBMounting Options:ISO-RACK8 and ISO-RACK16

$249.00

ISO-5B34-02

ISO-5B34-02

I0 To 100 deg C Input, 0 To 5V Output 100 Ohm Platinum. Analog Isolation Module Features:RTD input 1500 Vrms Isolation Low CostSpecifications:Input Range: 0C to +100C Output Range: 0-5V Input Offset: ± 0.02dC/ deg C Output Offset: ± 20μV°C Output Resistance: 50 Ohm Bandwidth, -3dB: 4 Hz Output Protection: Continuous Short to Ground Isolation: 1500 Vrms CMR at 50-60 Hz: 160 dB NMR at 50-60 Hz: 90 dBMounting Options:ISO-RACK8 and ISO-RACK16

$249.00

ISO-5B34-03

ISO-5B34-03

RTD (100 OHM) Input, 0 To 5V Output 0 To 200 deg C Analog Isolation Module Features:RTD input 1500 Vrms Isolation Low CostSpecifications:Input Range: 0C to +200C Output Range: 0-5V Input Offset: ± 0.02dC/ deg C Output Offset: ± 20μV°C Output Resistance: 50 Ohm Bandwidth, -3dB: 4 Hz Output Protection: Continuous Short to Ground Isolation: 1500 Vrms CMR at 50-60 Hz: 160 dB NMR at 50-60 Hz: 90 dBMounting Options:ISO-RACK8 and ISO-RACK16

$249.00

ISO-5B34-04

ISO-5B34-04

RTD 100OHM Platinum 0 To 600 deg C Input 0 To 5V Output, Analog Isolation Module Features:RTD input 1500 Vrms Isolation Low CostSpecifications:Input Range: 0C to +600C Output Range: 0-5V Input Offset: ± 0.02dC/ deg C Output Offset: ± 20μV°C Output Resistance: 50 Ohm Bandwidth, -3dB: 4 Hz Output Protection: Continuous Short to Ground Isolation: 1500 Vrms CMR at 50-60 Hz: 160 dB NMR at 50-60 Hz: 90 dBMounting Options:ISO-RACK8 and ISO-RACK16

$249.00

ISO-5B34-C-01

ISO-5B34-C-01

RTD 100 OHM Copper 0 To 120 deg C Input 0 To 5V Output Analog Isolation Module Features:RTD input 1500 Vrms Isolation Low CostSpecifications:Input Range: 0C to +120C Output Range: 0-5V Input Offset: ± 0.02dC/ deg C Output Offset: ± 20μV°C Output Resistance: 50 Ohm Bandwidth, -3dB: 4 Hz Output Protection: Continuous Short to Ground Isolation: 1500 Vrms CMR at 50-60 Hz: 160 dB NMR at 50-60 Hz: 90 dBMounting Options:ISO-RACK8 and ISO-RACK16

$249.00

ISO-5B34-C-02

ISO-5B34-C-02

RTD 10 Ohm Copper, 0 To 120 deg C Input 0 To 5V Output Analog Isolation Module Features:RTD input 1500 Vrms Isolation Low CostSpecifications:Input Range: 0C to +120C Output Range: 0-5V Input Offset: ± 0.02dC/ deg C Output Offset: ± 20μV°C Output Resistance: 50 Ohm Bandwidth, -3dB: 4 Hz Output Protection: Continuous Short to Ground Isolation: 1500 Vrms CMR at 50-60 Hz: 160 dB NMR at 50-60 Hz: 90 dBMounting Options:ISO-RACK8 and ISO-RACK16

$249.00

ISO-5B34-N-01

ISO-5B34-N-01

RTD 120 OHM Nickel, 0 to 300 deg C Input Features:RTD input 1500 Vrms Isolation Low CostSpecifications:Input Range: 0C to +300C Output Range: 0-5V Input Offset: ± 0.02dC/ deg C Output Offset: ± 20μV°C Output Resistance: 50 Ohm Bandwidth, -3dB: 4 Hz Output Protection: Continuous Short to Ground Isolation: 1500 Vrms CMR at 50-60 Hz: 160 dB NMR at 50-60 Hz: 90 dBMounting Options:ISO-RACK8 and ISO-RACK16

$249.00

ISO-5B35-01

ISO-5B35-01

100ohm RTD, +/-100 deg C in, 0V to +5V Out