Industrial Computers | PC Power supplies | ACE-890A


90W AC Input Power Supply
Input / Output Table : (at 50ºC)
*ACE/890A/890AP
Input Voltage:85~264V AC
Rated Load:+5V 10A +12 2.5A -12V 0.5A
Max Output:+5V 12A +12V 4A -12V 1A
*ACE-890C
Input Voltage:18~36V DC
Rated Load:+5V 10A +12 2.5A -12V 0.5A
Max Output:+5V 12A +12V 4A -12V 1A
*ACE-890P
Input Voltage:70V~132V DC
Rated Load:+5V 10A +12 2.5A -12V 0.5A
Max Output:+5V 12A +12V 4A -12V 1A
*ACE-890T
Input Voltage:36V~72V DC
Rated Load:+5V 10A +12 2.5A -12V 0.5A
Max Output:+5V 12A +12V 4A -12V 1A
*ACE-890V
Input Voltage:9V~16V
Rated Load:+5V 9A +12 2.5A -12V 0.5A
Max Output:+5V 12A +12V 4A -12V 1A
--ACE-890AP: min load +5VDC/1.5A, +12VDC,-12VDC/ 0.05A
Ripple and Noise :
Less than +5V@50mV, +/-12V@100mV Less than +5V@100mV, -12V@150mV, -12V@200mV (ACE-890AP)
Line Regulation :
The line regulation for each output is less than +/-1%, while measuring at rated loading and +/-10% of input voltage changing
Load Regulation :
Less than +/-1%@+5V and +/-5%@+/-12V
Efficiency :
Higher than 70%
Hold-up Time (ACE-890A/890AP) :
16ms (typical)@115V AC
Protection :
Over voltage protection. The trip point is around 5.7V~7.0V output
Operating Temperature :
-20ºC ~70ºC (Derating curve will occur 50ºC ~70ºC)
Storage Temperature :
-20ºC ~85 ºC
Altitude :
0~10,000ft
MTBF :
- ACE-890A : 268,358 Hours
- ACE-890P : 265,827 Hours
- ACE-890T : 269,884 Hours
- ACE-890C : 252,383 Hours
- ACE-890V : 245,424 Hours
- ACE-890AP : 50,000Hours
Safety : Meets UL 1950, CSA 22.2 No. 234, VDE EN 60 950
EMI :
- Meets FCC docket 20780 curve "B", EN55022 "B"
- Harmonic EN 61000-3-2 for ACE-890AP
EMS Standard (Designed to meet the following limits) :
IEC 801-2 15KV (Air Discharge)
- IEC 801-3, 10V/M
- IEC 801-4, 2KV
- IEC 801-5, 2KV
Dimensions :
89(W) x 39(H) x 152.4(D)mm; (3.5" x 1.5" x 6")
Specifications:
Input / Output Table
Input Voltage:85~264V AC
Rated Load:+5V 10A +12 2.5A -12V 0.5A
Max Output:+5V 12A +12V 4A -12V 1A
Ripple and Noise
Less than +5V@50mV, +/-12V@100mV Less than +5V@100mV, -12V@150mV, -12V@200mV (ACE-890AP)
Line Regulation
The line regulation for each output is less than +/-1%, while measuring at rated loading and +/-10% of input voltage changing
Load Regulation
Less than +/-1%@+5V and +/-5%@+/-12V
Efficiency
Higher than 70%
Hold-up Time (ACE-890A/890AP)
16ms (typical)@115V AC
Protection
Over voltage protection. The trip point is around 5.7V~7.0V output
Operating Temperature
-20ºC ~70ºC (Derating curve will occur 50ºC ~70ºC)